Slip Ring Induction Generator

Slip Ring Induction Generator

YRKK series slip ring induction generator can adjust starting torque and starting current through adjust rotor external connected additional resistance. Motor proper adopts box-type steel plate welding structure with light weight and good rigidity. This series of motor has advantages of compact structure, light weight, high efficiency, energy-saving, low noise and vibration, high reliability, long service life and convenient installation and maintenance, etc. The motors can operate when ambient temperature is -15℃~+40℃; the altitude ≤1KM; and monthly average air humidity ≤90% (If temperature is 25℃).
Send Inquiry

Description

Technical Parameters

Xi’an Simo Motor Co., Ltd. is one of the leading manufacturers and suppliers of slip ring induction generator in China. With abundant experience, we are committed to providing high quality customized products with competitive price. We warmly welcome you to buy bulk premium products made in China here and get quotation from our factory.

 

Brief Introduction

 

Slip ring insuction generator, also known as three-phase wire-wound rotor AC asynchronous motor, must be connected in series with a resistor or reactor in the rotor circuit of the motor, in order to make the starting current reduced, while the starting torque increased, the power factor increased, effectively improving the motor starting performance. Therefore, this kind of motor is usually chosen for dragging in machinery and equipment with large capacity and high requirement for rotating torque.

 

Slip ring motors in the process of operation of the heat is caused by the following reasons:

 

Insufficient cooling air volume of the slip ring. Coaxial installation with the slip ring fan blade should be accurately oriented, in line with the structural design standards and regulations. Fan blade orientation does not meet the standard, on the one hand, it will cause bearing vibration, on the other hand, it will cause the slip ring cooling air volume is not enough so that the slip ring and brush heating .

 

Slip ring airtight ducts are blocked or leaking. Slip ring guided air inlet holes need to be carefully cleaned to avoid the accumulation of dust, blockage caused by the slip ring cooling air volume is insufficient to cause brush and slip ring heating. The maintenance should use compressed air tube to clean the small holes of the slip ring one by one. Leakage of air ducts can also cause insufficient cooling air volume .

 

Brush quality and maintenance factors. Mixed use of brushes or brush boxes causes some brushes to heat up due to overcurrent, or even burn off the leads. Brushes are not carefully ground and polished during maintenance and replacement. Insufficient gap, brush jamming; gap is too large, and the contact surface of the slip ring does not match. Uneven length of brushes causes uneven current distribution, which is a common cause of slip ring heating. Therefore, it is necessary to blow and clean the slip ring regularly, and measure the brush current .

 

Brush box conductor insulation and equalization spring. Brush box conductive part and the fixed part of the insulating shims installed between the conductive part of the current in the conductive part and brush through and through the slip ring into the rotor. In operation, the accumulation of dust and carbon powder caused by the insulation ability to reduce or conductive, uneven distribution of the resistance of the brushes caused by localized heat. Brush box in the uniform pressure spring after using a certain period of time, there will be uneven pressure, deformation, cracks, loose spring and so on, resulting in brush box overcurrent heating .

 

Slip ring is not round or surface roughness caused by friction heat. Slip rings are not round or surface roughness caused by turning during maintenance, which is easy to cause friction heat .

 

Brush heating caused by bearing vibration. Brushes vibrate with bearings, resulting in uneven friction on brush contact surfaces, loose leads and springs, and localized sparking, further aggravating brush heating.

 

Main Technical Parameters

 

Frame

H710mm

Power Scope

1250kW~1800kW

Voltage

6kV

Frequency

50Hz, 60Hz

Number of Poles

10P

Speed

595rpm

Cooling Mechod

IC611

Protection Grade

IP54

Insulation Class

F(155℃)

Duty

S1

Mounting Type

IM B3

 

Outline Dimensions

 

drawing of slip ring induction generator

 

outline dimension of slip ring induction generator

 

Motor Parameters

 

technical data of slip ring induction generator

 

 
 
 

 

Applications

 

 

 

cement(001)

Cement

power station(001)

Power Station

water conservation(001)

Water conservation

steel(001)

Steel

product-1-1 CHOOSE SIMO, CHOOSE QUALITY!

 

Hot Tags: slip ring induction generator, China, suppliers, manufacturers, factory, customized , quotation, low price, in stock, made in China, hvac electric motors, 6kv electric motor, industrial electric motors, hvac motor, 500kw motor, high voltage induction motor

Send Inquiry