Wound Rotor Induction Generator Wind Turbine

Wound Rotor Induction Generator Wind Turbine

Rotor type JS motor is a wire-wound squirrel cage three phase motor. The rotor of an induction motor is connected to an external varistor through a slip ring and a brush, which can improve the start-up performance or speed regulation by adjusting the resistance.Compared with the cage rotor, its structure is more complex but its control flexibility is higher. This series of motors meets industrial-grade protection standards.
Send Inquiry

Description

Technical Parameters

Title:

JS Low Voltage Squirrel Cage Three Phase Motor

 

 

Brief Introduction

Medium-sized JS motors use roller bearings at the load end (generally used in high-load conditions), and ball bearings at the non-load end.The quality of the bearing itself affects the service life of the motor.The installation of motor bearings is good or bad, which will directly affect the accuracy, life and performance of the bearings, it usually used as wound rotor induction generator wind turbine.

 

 

Main Technical Parameters

Frame:

#14

Power Scope:

560~800 kW

Voltage:

380V

Frequency:

50Hz, 60Hz

Number of Poles:

6 P

Speed

600 rpm

Cooling Method

IC01

Protection Grade

 IP23,IP00

Insulation Class

F(155℃), H(180℃)

Duty:

S1, S4, S5, S6, S9

Mounting Type

B3/V1

 

 


Why choose Simo Brand JS series of Motor?

 

JS motor, usually used to drive low-load mechanical equipment, such as fans, pumps, compressors, wound rotor induction generator wind turbine, etc.The motor can adjust the speed by adjusting the voltage and frequency to adapt to different working loads.

 

Small and medium-sized squirrel cage asynchronous motors (below 100kW) use cheaper aluminum instead of copper, and cast the rotor conductors, short-circuit rings, and fans into one to become cast aluminum squirrel cage rotors.Squirrel cage asynchronous motors have a simple structure, reliable work, and easy to use and maintain, so they are widely used. The windings of the wire-wound rotor are similar to those of the stator, but the three-phase windings are connected in a star shape, and the three end wires are connected to the three copper slip rings mounted on the shaft, which are connected to the external circuit through a set of brushes.

 

This series of motors which used as wound rotor induction generator wind turbine, can add thermal protection or heaters according to user requirements. Among them, the windings of the H160~H400 motors can be embedded with PTC temperature measuring elements or Pt100 temperature measuring elements according to user requirements.H280~H400 motors can be embedded with Pt100 bearing temperature measuring components according to user requirements.H160~H400 motors can install heaters according to user requirements.The H355~H400 motor thermal protection and heater wiring share an independent junction box, which is located on the right side of the motor. The thermal protection and heater of the rest of the base number share a junction box with the main power supply.The H180~H400 motor which used as wound rotor induction generator wind turbine, has an oil injection and exhaust device, and the motor junction box is located at the top of the base. It can also be made into a right outlet or a left outlet according to user requirements.

 

For grounding flexible wires, they must be green and yellow insulated wires, and other wires must not use this color mark.The logo of the outlet end of the motor shall comply with the provisions of GB 1971, and shall be engraved on the outlet end or marked with a label sheet (tube). For motors with wiring boards, the logo shall be engraved on the wiring board at the same time, and shall not be replaced by a separate hanging label sheet (tube). The outlet terminal logo of the motor can be represented by a color line consistent with the wiring diagram.

 

The lead-out wires of capacitors, centrifugal switches, etc. on the motor should have a sign of the outlet end.All signs on the motor can be printed, engraved, pressed or other equivalent engraving methods. They must be clear, clear, durable, and not easily erased during the entire service life of the motor.Whether it meets the requirements should be tested and determined according to the following methods. First use a wet cotton cloth soaked in water to wipe the logo for 15s, and then use a cotton cloth soaked in gasoline to wipe for 15s.

 

The logo of the motor should remain clear and legible after the above-mentioned tests and all the tests specified in this standard, and cannot be easily removed. The nameplate should not be easy to move and may cause crimping that falls off.Each product must have a supporting manual when it leaves the factory.If it is a targeted supply in batches, the entire contents of the manual can be reflected in the manner agreed by both parties, but at least one manual is required for each box of products.All possible dangerous conditions and troubleshooting conditions should be indicated on the product manual to avoid safety accidents caused by improper use by users.

 

 


Production Details

 

Frame

  • Box structure frame, easy for maintaining and installation

  • Flexible for special installation dimensions

  • Customizable outlook and dimensions

frame1(001)


stator 2(001)

Stator

  • 99.9% pure copper winding for stator to ensure the output power and efficiency

  • Excellent insulation system with 5 more processing flows

  • All the windings are fitted in by handwork to ensure all slots are full and avoid any possible winding flaw.


Rotor

  • Aluminum casting rotor with high quality silicon steel rotor core to assure induction efficiency

  • Copper bar rotor is available for YKS motor

  • Well and precisely machined shafts with good capacity of strength and toughness

rotor(001)
testing(001)

Testing

  • All motors must pass the piece testing before painting and packaging

  • Type tests will be regularly performed for each series, more often for new developed series and variants.


Package and delivery

  • All motors will be packaged well before delivery

  • Plastic cover inside, vacuum tin foil outer and then solid wood box

 packaging(001)

 

Applications

Simo JR motor can be used and perform well where heavy starting load is needed, speed adjusting when operating, insufficient power distribution capacity or the squirrel-cage rotor motor cannot be started smoothly. It can drive different machinery such as blowers, compressors, pumps, crushers, ball mills and other equipment in coalmines, machinery industry, power plants and various types of industrial and mining enterprises.  More application details, click here.

 

 

cement(001)

Cement

power station(001)

Power station

mining(001)

Mining

water conservation(001)

Water conservation

product-1-1 CHOOSE SIMO, CHOOSE QUALITY!

 

Hot Tags: wound rotor induction generator wind turbine, China, suppliers, manufacturers, factory, customized , quotation, low price, in stock, made in China, rolling mill motor, IEC ac motor, industrial electric motors, 6kv electric motor, dc induction motor, cement DC motor

 

Type

Power

Speed

Stator Current

Efficiency

Power Factor

Start Current

Start Torque

Max. Torque

Cooling Air Volume

Rotor Fly-wheel Torque

Driven Machine Max.Permissive Fly-wheel Torque

Weight

Rated Current

Rated Torque

Rated Torque

KW

r/min

A

%

COSФ

A

Times

Times

m3/s

kg·m2

kg·m2

kg

380V  1000r/min (6极)

JS146-6

560

988

1040

94

0.87

6.0

1.0

1.8

 

151

 

 

JS147-6

630

989

1168

94.2

0.87

6.0

1.0

1.8

 

175

 

 

JS148-6

710

988

1297

94.5

0.88

6.0

1.0

1.8

 

194

 

 

JS1410-6

800

989

1458

94.7

0.88

6.0

1.0

1.8

 

213

 

 

Send Inquiry